Armed
Watching every pour
Live vibration and the detection model on one panel at the deck. Grey means all is well.
Ladle slag detection
SlagIQ listens to every pour, cuts out the plant noise and warns your crew as the vortex forms, before slag reaches the tundish. If a sensor or cable fails, you know that second. And every heat you pour makes it sharper at your caster.
You're on the list. Two more details help us plan your prototype. Tell us about your caster
The first prototype systems go to the first plants on the list. No cost, no commitment.
Scroll to watch it catch slag
Armed
Live vibration and the detection model on one panel at the deck. Grey means all is well.
Slag detected
SlagIQ catches the vortex at the sensor before slag reaches the tundish. The panel takes over, the horn and lamp fire, and the relay trips for your gate logic.
Most slag detectors don't fail loudly. They drift. The screen still looks normal, and nobody finds out until there's slag in the tundish. Once the crew stops trusting the horn, every ladle closes on habit.
Close early and you leave steel in the ladle. Close late and you carry slag into the tundish. SlagIQ is built so your crew closes on the alarm, not on habit.
A single threaded stud backs off with heat and cable tugs. The signal fades and nothing on the screen changes.
SlagIQ: four bolts and full flange contact keep it coupled. If coupling ever slips, SlagIQ flags it before it costs you a heat.
How SlagIQ mountsSensors that have been overheated drift for good. The alarms get a little worse every week.
SlagIQ: the sensor watches its own temperature and signal, and asks to be swapped before it costs you a heat.
How SlagIQ watches itselfA half-broken analog cable doesn't fault. It picks up drive noise for months instead.
SlagIQ: digital from sensor to cabinet. A damaged cable faults that second.
Why SlagIQ is digitalPeak-to-peak logic fires on normal operator moves and crane noise, so crews learn to ignore the horn.
SlagIQ: learns steel, slag, gate trims and ladle closes apart on your caster.
How SlagIQ learnsThe operator panel
The cabinet panel is built to ISA-101 high-performance HMI practice. It stays grey while everything is normal and uses colour only when somebody needs to act. Big states, big buttons, made for gloves.
Casting, armed, healthy. Live vibration and detection on the left, relay, horn and lamp ready on the right. Arming follows the pour, with a timer if your practice wants one.
Slag detected. The whole screen takes over, the horn and lamp fire and the relay trips for your gate logic. The alarm latches until someone acknowledges it.
Sensor lost. SlagIQ never pretends to watch a pour it can't see. It drops straight to Fault and tells the crew detection is unavailable, so they know to watch the stream.
Heat review. When the pour ends, the panel asks what really happened. A few taps while it's fresh, and that answer trains the next model.
Want a live walkthrough of the panel with your crew's questions?
Book a panel walkthroughThe smart sensor
The sensor bolts to the shroud manipulator, right under the ladle nozzle where the vortex shows up first. It goes on in minutes with a high-temperature magnet base for a trial, then a weld plate for good.
Power and data share one Cat6 line with a sealed M12 connector, run back along the boom in silicone-coated fibreglass fire sleeve. No analog signal to pick up drive noise. Damage the cable and the cabinet faults that second. Test it with an ordinary network tester.
The electronics are cast solid inside the housing, so nothing can rattle, shift or take on water. Sealed to IP67 against cooling-water spray, splash and condensation. Bare stainless throws back the radiant heat that black housings soak up.
A wide square flange clamps flat to the plate with four bolts, so the vibration path stays tight heat after heat. No single stud to back off, no gasket to soften.
SlagIQ learns what a good pour sounds like on your caster. The day the signal drifts from it, from heat, a loose mount or a tired cable, it flags the sensor and tells you to swap it. A green light on the sensor means healthy. Red means look at me.
Loading 3D view
It measures in full 3D and knows which way is up, so mounting angle never matters.
Want the drawings and mounting details for your manipulator?
Get the sensor spec sheetAdaptive noise cancellation
On a casting deck the loudest thing in the signal is rarely the steel. Cranes, fans and ladle moves leak into every vibration sensor and bury the vortex that comes right before slag. An arc furnace in the same building can sing in exactly the band the vortex lives in.
SlagIQ measures the plant's own noise and subtracts it in real time, so the model hears the stream. Add a floor reference sensor and it cancels building vibration too.
Multi-modal detection
Four PoE ports on the cabinet take more SlagIQ sensors plus vision and IR cameras. One model weighs all of them on every pour, so a vortex that hides from one sense shows up in another.
If one input faults, the others keep watching and the panel says which one is down.
Human in the loop
Most slag detectors are frozen the day they're commissioned. SlagIQ keeps learning your caster, your grades and your crew. It learns steel, slag, a gate trim and a ladle close apart, heat after heat, and your engineers decide when a better model goes live. The longer it runs, the fewer false alarms your crew sees and the fewer ladles close early.
Slag this heat? Did the alarm come on time? Did you close on it? A few taps on the panel while it's fresh, about ten seconds. It can be skipped and never holds up the next ladle.
Every answer lands in a review queue with the recording, spectrogram and alarm timing. Accept it in one click or correct it. Hits, misses and false alarms are counted for you.
Each confirmed heat becomes a training label. SlagIQ retrains and benchmarks dozens of model types on your plant's own heats and puts the best challenger up against the model you run today.
Nothing changes on the deck until someone at your plant reviews the benchmark and approves it. Roll back to the previous model in one step.
A full audit trail shows which heats trained which model, who approved it and when it went live. When someone asks why the alarm fired, you have the answer.
Buy SlagIQ once. Every model the cabinet trains on your heats comes with it for as long as you run it. Perpetual licence, no mandatory subscription. When a more advanced model needs more GPU than the edge has, it can be trained on cloud compute, and you decide whether your data goes there.
See how Continuous Intelligence would learn on your heats
Reserve a Continuous Intelligence pilotIntegration
It knows when you're casting from its own signal. No ladle-weight signal or PLC handshake needed to start.
More protocols and systems are on the way. Tell us what your plant runs.
OPC UA, EtherNet/IP, Siemens S7, Modbus TCP and MQTT for your PLC and historian. Isolated discrete I/O for the horn, the lamp, your gate interlock and a heartbeat to the PLC.
It runs fully offline with no inbound connections. Remote support runs over a VPN your plant switches on and off from the floor, and every session is logged.
Containerised end to end. Updates arrive over that plant-controlled VPN or on signed media, and roll back in one step.
Every cable runs in silicone-coated fibreglass fire sleeve, and system health watches each one. A damaged cable raises a fault on the panel instead of quietly adding noise.
Check SlagIQ against your PLC, historian and OT security setup
Talk to an engineerPrototype systems are being built now, and they go to the plants that join the list first. Joining costs nothing and commits you to nothing.
No outage: the magnet plate goes on between sequences with no welding. You provide power for a wall-mount cabinet near the deck and one cable run of up to 100 m. It runs in advisory mode beside your current practice, with no gate tie-in needed, and your crew answers a ten-second review at the end of each heat. From the first heat, those answers start training a model on your caster's own pours.
Yes, if you want it to. Isolated outputs can drive your gate interlock directly, or SlagIQ can talk to your PLC over OPC UA, EtherNet/IP or S7. Your controls team decides the logic. On a power loss or fault, the fault and heartbeat contacts open, and SlagIQ never closes your gate by itself. The alarm, horn and lamp fire either way, and the alarm latches until someone acknowledges it.
The cabinet faults that second, the light on the sensor turns red, and the panel shows detection unavailable, so nobody casts on a blind system. SlagIQ also flags a sensor whose signal is drifting before it fails, and a swap is four bolts and one connector.
SlagIQ tracks the state of the pour from its own signal. When the shroud is off or the ladle is being opened, it holds detection rather than arm on a signal it can't trust, and the panel says so. With a vision or IR camera on the cabinet, the camera keeps watching an open pour. If the manipulator swings away mid-heat, the panel shows detection paused until it is back on the nozzle.
No. SlagIQ tells casting from not casting with its own signal and runs standalone.
From the first heat. SlagIQ runs a baseline detector on day one, and every review your crew answers starts training a model on your own caster. You watch the benchmark climb in analytics, heat by heat.
You do. Your heats and your models stay at your plant unless you turn on cloud training, and they are never pooled with anyone else's without your written consent.
Models SlagIQ trains on the cabinet at your plant come with the system. Some more advanced models need more GPU compute than an edge computer has. Those can be trained on cloud compute over your plant-controlled VPN, and whether to use it is your call.
No. It runs fully air-gapped with no inbound connections. The VPN for remote support stays off unless your plant turns it on.
Prototype program
We're building the first prototype systems now and choosing the plants that will run them. Prototypes run in advisory mode beside your current practice. No outage, no gate tie-in needed.
You get the full report at the end of the trial.
No commitment and no sales sequence. An engineer reads every request.
We'll be in touch within two working days to set up a call. If you asked for the spec sheet, it comes with that first email.